Detailed Product Description
I. Brief Description
The UV lamp is designed for non-destructive testing of fluorescent magnetic particle inspection , from the workpiece 381 mm light intensity greater than 1000uW/cm2. This product is lightweight, easy to operate, the use of imported long-life UV lamp.
II. Technical performance
Output wavelength:365nm;
Power Consumption: 125W;
Power supply: 220V 50 HZ;
Warm-up time: five minutes;
The need to re-ignite the delay: five minutes;
Holding a lampshade weight: 1.2 kg
Controller Weight: 2.6 kg
Controller Dimensions: 250mm×160mm×110mm
III. Operation and maintenance
Instrument front panel has a three-core socket for output socket; backend a three-core socket for power input socket.
When used, the first fixture on the front panel output jack insert and tighten, then insert the input socket, then plug the power distribution board and tighten the corresponding 220V outlet, Turn the power switch on the front panel, under normal circumstances, the voltmeter on the front panel will indicate the value of the supply voltage, such as voltage is normal, the UV lamp will be issued here, and gradually increased, the length of time with the ambient temperature, to be constant after the lights , can be put into use.
It is used at ambient temperature -5 to +40 ℃, humidity no higher than 80% of the conditions observed indoor shading, such as on-site operation shall be provided valance.
At the end of use, first turn off the switch on the front panel, and then unplug the lamp to cool sufficiently upon placement.
IV. Cautions
Once the power is turned on , will enter the working state, in the course has to cut off the power, otherwise even then power the bulb, it will not work, as in the above case, you should turn off the power switch, and then turn on until about 5 minutes, then re-lit the lamp.
Operating personnel in the operation, must wear PPE protection against ultraviolet radiation, the skin should not be exposed to light for a long time, so as not to cause burns.